Bộ điều khiển van khí nén, bộ van kit Gestra vietnam, mã: NRGS 16-1

Bộ điều khiển van khí nén, bộ van kit Gestra vietnam, mã: NRGS 16-1

Bộ điều khiển van khí nén, bộ van kit Gestra vietnam, mã: NRGS 16-1

Số lượt xem: 204

Exion Vietnam

Địa chỉ: TP HCM
Điện thoại: 0975291433
Fax:
Email: chuotdientu815@gmail.com
Website:

Equipment for steam and hot water generator

 LIÊN HỆ MUA HÀNG, Chúng tôi cung cấp tất cả thiết bị của hãng này vui lòng liên hệ để được hổ trợ tốt nhất.
SĐT: 0975 291 433 Gặp Mr Kiệt
Mail: anhkiet815@gmail.com
Web: https://valve-vietnam.000webhostapp.com/home/

Conventional

PN 40-160 limit level

Water level limiterHigh water alarm NRG 16-50 to NRG 19-50 / NRS 1-50
NRG 16-51 to NRG 19-51 / NRS 1-51
PN 40-250 control level NRG 26-11 / NRR 2-2
LD 144 / KS 92-1
Limit temperature TRG 5-53 to 5-57 / TRS 5-6
Measure conductivity / desalination
PN 40-160
PN 40-63
LRG 16-4 to 19-1 / LRR 1-5 /URS 2
LRGT 16-1 to 17-1 / KS 90
Desalination PN 40-320 electrically BAE 46 to BAE 211
Blowing-down PN 40-250 manually PA 46 to PA 111
pneumatically MPA 46 to 110

BUS-technology

PN 40-320 limit level
Water level limiterHigh water alarm NRG 16-40 to 111-40 / NRS 1-40
NRG 16-41 to 19-41 / NRS 1-41
PN 40-250 control level NRG 26-40 / NRR 2-40 / URB
Limit temperature TRG 5-63 to 5-69 /
TRV 5-40 / NRS 1-40.1
Measure conductivity / desalination
PN 40-63 LRG 16-40 to 17-40 /
LRR 1-40 / URB
Desalination PN 40-320 electrically BAE 46 to BAE 211
Blowing-down PN 40-250 pneumatically MPA 46 to 110

GESTRA control technology

NRGS 16-1NRGS 16-1

Level controlling

In condensate and feed water tanks, etc.
NRG 11-1, PN 6, G1, 4 switching points, PP on/off, flooding, dry run
NRGS 16-1, PN 40, G1, 4 switching points
NRG 11-2, PN 6, G1, 3 switching points, PP on/off, lack of water for low pressure steam boilers up to 0.5 bar
BAE 46 / BA 46BAE 46 / BA 46

Desalting valve

Special designs for specific tasks, i.e. low-noise and low-wear level relaxation.
BA(E) 46 PN 40 DN 15-50 C 22.8
BA(E) 47 PN 63 DN 15-50 C 22.8
BA(E) 210 PN 250 DN 25 C 22.8
BA(E) 211 PN 320 DN 25 13 CrMo 4 4
ZK(E) 29 PN 160 DN 50 13 CrMo 4 4
MPA 46 / PA 46MPA 46 / PA 46

Blow-down valve

The GESTRA security concept, i.e. boiler and spring pressure ensures a safe close and the downstream radial level nozzle for low-wear operation.
(M)PA 46 PN 40 DN 20-50 C 22.8
(M)PA 47 PN 63 DN 25, 40, 50 C 22.8
(M)PA 110 PN 250 DN 25 13 CrMo 4 4

Surveillance on contamination inleakage

In closed loops (emergency power generators, etc.)
SurveillanceORGS 11-2, PN 6, C 22.8
In open circuits and condensate systems
Surveillance
There is a risk of inleakage by oils, grease, etc.:
OR 52-5, PN 10, G 3/8, GG
OR 52-6, PN 10, G 3/8, 1.4580
There is a risk of inleakage by acids, alkalis, etc.:
Electrode LRG 12-1, PN 10, G 11/4
Transmitter LRT 1-6b
Limit switch URS 2

 