Technical data
Applied standards
EN ISO 13849-1, EN 60947-5-1, EN ISO 14119
Enclosure
thermoplastic, glass-fibre reinforced, shock-proof, self-extinguishing UL 94 V-0, weathering resistant, UV stabilised
Switch type
type 2
Coding level
low coding
Degree of protection
IP66/IP67 (IEC/EN 60529)
B10d (10 % load)
2 million
TM
max. 20 years
Switching system
slow action, positive break NC contacts A
Switching elements
2 NC contacts, type Zb
Connection
screw connection terminals
Cable cross-section
0.34 ... 2.5 mm² (incl. conductor ferrules)
Cable entry
1 x M20 x 1.5 (M16 x 1.5 on request)
Rated impulse withstand voltage Uimp
6 kV
Rated insulation voltage Ui
500 V
Conventional thermal current Ithe
10 A
Utilisation category
AC-15; DC-13
Rated operating current/voltage Ie/Ue
AC: 24 V-10 A/120 V-6 A/400 V-4 A
DC: 24 V-6A/125 V-0.55 A/250 V-0.4 A
Minimum electrical load: 5 V/10 mA
Short-circuit protection
10 A gG/gL fuse
Conditional short-circuit current
1000 A
Operation cycles
max. 1800/h
Mechanical life
> 1 million operations
Ambient temperature
–30 °C … +70 °C